Epoxy Injection
Repair of severely corroded 6” water injection flow line in a subsea manifold. Installation of split clamp with soft packers
and injection of the epoxy in order to replace and support the pipe wall at the corroded areas.
OPERATIONAL PARAMETER
Main operational parameters of the leaking location:
- Depth: 150 m
- Fluid: Water
- Maximum operation pressure: 250 bar
- Maximum flowing temperature: 20°C
- Seawater temperature: approx. 4°C
- Epoxy volume: 2 – 5 litres each clamp
EPOXY SKID FUNCTION
Parameters
- 2 + 2 cylinders for resin & hardener
- Hydraulic operated
- Static mixer of the components
- ½ hoses and stabs / receptacles
- Material; aluminium / stainless steel
- ROV / diver operation