Epoxy Injection

Repair of severely corroded 6” water injection flow line in a subsea manifold. Installation of split clamp with soft packers
and injection of the epoxy in order to replace and support the pipe wall at the corroded areas.

OPERATIONAL PARAMETER

Main operational parameters of the leaking location:

  • Depth: 150 m
  • Fluid: Water
  • Maximum operation pressure: 250 bar
  • Maximum flowing temperature: 20°C
  • Seawater temperature: approx. 4°C
  • Epoxy volume: 2 – 5 litres each clamp

 

EPOXY SKID FUNCTION

Parameters

  • 2 + 2 cylinders for resin & hardener
  • Hydraulic operated
  • Static mixer of the components
  • ½ hoses and stabs / receptacles
  • Material; aluminium / stainless steel
  • ROV / diver operation

Contact for this product is:


Pål Angell Bergh: Department Manager SubSea - IK Norway
T: +47 51 44 67 18     eMail: Pal.Bergh@ik-worldwide.com